Powering the
Warfighter
Enercon's Tactical Electrical Power (TEP) solutions
are second to none.
The Power Behind the Power.
Enercon is a small business with big capabilities. We ensure the United States Armed Forces and its Allies receive reliable power solutions for critical operational systems to defend assets domestically and abroad. We do this by working with our defense partners in the design, fabrication, and testing of specialized power solutions necessary to maintain overwhelming Tactical, Operational, and Strategic advantages over adversaries.
Since 2009, Enercon is the driving force behind the Missile Defense Agency’s THAAD-PPU (Terminal High Altitude Area Defense - Prime Power Unit) for the ballistic missile defense system. The highly mobile power unit provides primary power to the AN/TPY-2: Army Navy/Transportable Radar Surveillance, which detects, tracks, and discriminates against incoming ballistic missiles.
The combined units of the THAAD-PPU and the AN/TPY-2 have a flawless performance against all classes of ballistic missiles including the January 2022 attacks on UAE allied forces.
To date, we have successfully delivered 23 PPUs to military deployments around the globe.

The Prime Power Unit (PPU) for the AN/TPY-2 Radar of the THAAD Missile Defense System is being loaded onto a C-17.


Standby Power for the Pentagon, Washington, D.C.
Scope of Project:
An initial order was received for (3) 40 ft high cube ISO shipping containers to be utilized as generator set enclosures. Each unit contained a single CAT 3516 Diesel Genset 1825kW @ 5kV, sound attenuated to approximately 85 db(A) at 15 meters, installed on a tri-axle container chassis equipped with the followings:
-
Internal, critical grade silencer, including all piping
-
1250 gallon capacity fuel tank
-
Separate control room containing the engine paralleling controls as well as the generator 5 kV breaker. The control room is insulated and heated.
-
The container interior AC requirements are wired to an internal distribution panel board with individual circuit breakers along with a main circuit breaker for the utility connection.
-
The package is shipped with an access stair set plus support jacks for use when the container is “dropped”, no tractor is left under the trailer.
-
To date, we have provided 7 container units in this configuration to be used by the U.S. Army.
Areas of Technical Expertise
Integration
-
Maximized Space Claim
-
Product Weight Reduction
-
Solutions up to 100 Tons
-
Transport Requirements
-
Thermal Management
-
Airflow Management
-
Shelter Systems
-
Energy Control Systems
-
Power Distribution
-
Electrical Assemblies
-
Air Conditioning System
Electrical
-
Power Generation up to 2.5 megawatts
-
15kV Electrical Systems
-
SCADA Systems
-
PLC Systems
-
HMI Systems
-
System Safety
-
Testing
-
Field Support
Environmental
-
NBC Resistant Coatings
-
Temperatures at -40C
-
Temperatures at +50C
-
Saline Atmospheres
-
EMI Protection
-
High Altitude
-
Water Reclamation & Odor Elimination
MIL-SPEC Experience
MIL-C-5541 - Chemical Conversion Coatings on Aluminum and Aluminum Alloys
MIL-HDBK-454 - General Guidelines for Electronic Equipment
MIL-C-22750 - Coating, Epoxy, VOC
MIL-STD-1366 - Interface Standard for Transportability
MIL-STD-188 - Interoperability and Performance Standards for Medium and High-Frequency Radio Systems
MIL-HDBK-419 - Grounding: Bonding and Shielding for Electronic Equipments and Facilities
MIL-STD-209 - Department of Defense Interface Standard for Lifting and Tiedown Provisions
MIL-STD-810 - Environmental Engineering Consideration and Laboratory Test
MIL-STD-1472 - Human Engineering
MIL-STD-705 - Mobile Electic Power Systems
MIL-DTL-38999 - Contractors, Electrical, Circular, Miniature, High-Density Quick Disconnect (Bayonet Threaded, and Breech Couplings), Environment Resistant Removable Ceimp and Hermetic Solder Contacts, General Specification.
MIL-HDBK-1784 - Mobility, Towed, and Manually Propelled Support Equipment
MIL-DTL-83528 - Gasketing Material, Conductive, Shielding Gasket, Electronic, Elastomer, EMI/RFI
MIL-STD-130 - Identification Marking of U.S. Military Property
MIL-STD-461 - Electromagnetic Interference Characteristics Requirements for Equipment
MIL-HDBK-784 - Guidelines-Design to Minimize Contamination and to Facilitate Decontamination of Military Vehicle and other Equipment: Interiors and Exteriors
MIL-STD-464 - Interface Standard: Electromagnetic Environmental Effects, Requirements for Systems
MIL-HDBK-1791 - Designing for Internal Aerial Delivery In Fixed Wing Aircraft
MIL-PRF-22750 - Performance Specification: Coating, Epoxy, High-Solids
MIL-STD-882 - System Safety
Primary NAICS Codes
238210 - Electrical Contractors and Other Wiring Installation Contractors
335311 - Power, Distribution, and Specialty Transformer Manufacturing
335313 - Switchgear and Switchboard Apparatus Manufacturing
335314 - Relay and Industrial Control Manufacturing
335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
532490 - Other Commercial and Industrial Machinery and Equipment Rental and Leasing
Approved Supplier of









Powering Industry Around the Globe
With over 50,000 projects completed and deployed worldwide in 110 countries, Enercon continues to help all industries overcome their toughest critical power challenges. Learn how we can help you do the same!
TACTICAL POWER • FUEL EFFICIENCY •
WATER TREATMENT • EXTREME ENVIRONMENT
WASTEWATER • LANDFILL • MICROGRIDS •
SCHOOLS • EMBASSIES • CORRECTIONS
HOSPITALS • UNIVERSITIES • DATA CENTERS •
CASINOS • COMMERCIAL CONSTRUCTION
OIL & GAS • MANUFACTURING • AGRICULTURE • MINING • TRANSPORTATION
WIND • SOLAR • HYBRID POWER GRIDS
CRITICAL POWER BACKUP • POWER RENTALS